HELIX DN9340E/DN9344E Remote Control Software
User Guide
63 of 65
8 Highlight your device in the
device list and double-click to
access the Device Details,
Web Configuration and Telnet
Configuration tabs.
9 Switch to the Web Configuration
tab and click Go to connect to
the UDS1100’s web
configuration pages (shown
below).
10 Under the Channel 1 heading on the left-
hand side of screen, click on Serial Settings
to access the Serial Settings screen.
11 Make the following settings in the Port
Settings section:
Protocol: as required (with Solo
Tracking you must use the
front panel RS-232 input
for the converter)
Baud Rate: “38400”
Data bits: “8”
Parity: “None”
Stop bits: “2”
Flow control: “None”
Click OK. (Done! will appear next to OK
to showthat settings have been stored.)
Important!
Remember to change the Serial Protocol if you
change from RS-232 to RS-485 input or vice
versa.