Page view 18
HELIX DN9340E/DN9344E Remote Control Software
User Guide
19 of 65
To Bypass the Dynamic EQ on the current channel
Tick the Bypass check box in the upper Dynamic tab by clicking on it.
To shape a Dynamic EQ section
1 Click on its control panel in the lower Dynamic tab so that it is highlighted. (Dynamics
initially default to 1kHz).
2 Scroll or type in the Lo Threshold (quiet) and the
Hi Threshold (loud) for the signal level.
3 Left click on the target and drag it to the
required frequency and boost/cut. The
currently selected threshold is marked at the
bottom left of the target. The values in the
Dynamic control panel track the target.
4 Using the double-headed arrow to the top right
of the target, toggle to the other threshold.
5 Left click on the target and drag it to the
required frequency and boost/cut.
6 Right click on the target and drag the mouse up/down (the target
remains still) to increase (narrow) or decrease (widen) the Q factor or
choose a shelf response from the EQ slope drop down menu in the
Dynamic control panel.
Note
The Q field is disabled when an EQ slope is selected; reset the EQ
slope to Off to enable the Q field.
7 If required, fine tune the settings at the PEQ panel by scrolling the Frequency, Level and Q
fields.
8 Specify the response to sudden rises in dB level by setting an Attack time between 20 µs
and 100 ms using the scroll to increment in allowable steps for the sample rate or by typing
in a value (use u for µ). Typed in values are automatically adjusted to the nearest
allowable value.
9 Specify the response to sudden drops in dB level by setting a Release time between 10 and
2000 µs, using the scroll to increment in steps of 10 µs or by typing in a value.
Adjusting the Dynamics: The target provides coarse visual adjustment, the scrolls enable fine
tuning. If you know the exact values you wish to apply to, it may be quicker to type the values
into the Dynamic panel. Frequencies in kHz should be entered with a ‘k’ suffix, that is, 12.5k
for 12.5 kHz. Frequencies will be automatically adjusted to the nearest valid increment.
To activate the target on the other Dynamic
Click anywhere on its Dynamic panel. The selected panel becomes highlighted and the
target cursor switches to the associated Dynamic, on the same threshold as your last edit.
Hint
Click the arrow to
switch between
high (HI) and low
(LO) thresholds