HELIX DN9340E/DN9344E Remote Control Software
User Guide
20 of 65
To switch a Dynamic section out of the circuit
1 Tick the Out check box at the bottom
right-hand corner of its Dynamic control
panel.
The Dynamic is faded to grey on the graph and
its contribution is removed from the overall
frequency response. The target remains active
so that it can still be adjusted while switched
out.
2 To switch it in again, clear the check box.
5.4 Filters
To switch to the Filter view
Click on the Filter button of the Channel A or B Navigation Strip, as required. (If staying on
the same Channel, you may prefer to click on a Filter tab).
The upper Filter Mode tab is used to set the bypass state and the Graph display mode (when a DN9340)
for the current channel. The lower Filter Shaping tab provides a control panel for each added Filter.
Filter settings can also be adjusted at the display by using the target cursor.
Dynamic
switched out
The black graph
shows overall
response. The
red graph shows
the response of
the selected LO
or HI Dynamic
The Filter freq,
level, and Q are
adjusted by
dragging the
target’ o
r
setting values
Tick the check box to switch
the filter out of the circuit
Filter Mode tab
Choose a notch, pass
or shelf filter
Filter Shaping
tab
Control panels
appear as you
add Filters