HELIX DN9340E/DN9344E Remote Control Software
User Guide
43 of 65
7.6.2 Online Operation
Important!
We recommend that you always save your show file settings before going online, so that you have the
option of reverting to previous settings after a ‘Get All’ synchronisation.
The slave Units in the network can be set online/offline, individually or globally, as required.
To set a particular unit online (and Get All/Send All settings)
1 Switch to the respective HELIX AddIn.
2 Click on the large red Go Online button to the right of
the Channel Navigation Strips.
3 At the Synchronise Data prompt, choose to
download the PC settings to the Unit (Set All), or
upload settings from the Unit to overwrite the
current PC settings in the respective AddIn Devices
(Get All).
4 Click OK.
When contact is successfully established the button turns green and the text
changes to Go Offline, while at the HELIX unit the NETWORK LED shows
communication activity. If the connection is not immediate the button turns
yellow and displays a ? while it tries to establish wireless contact.
Version
Update
In response to customer feedback, the online/offline colour coding has been reversed from
earlier versions. Also, the data synchronisation ‘direction’ has been changed; ‘Get All’ is
now the default option.
If online contact cannot be established, an error message is returned. This must be acknowledged;
thereafter HELIX RCS will continue polling the unit unless taken Offline by clicking on the yellow ?
button. Continuous polling is primarily designed to facilitate wireless communication, where the link
may briefly disappear, for example, when you walk behind an obstructing object. However, it can also
be useful when fault finding cabled communication, as the button will turn green as soon as the problem
is corrected.
Warning!
Changes should not be made to equalisation settings at the unit while the HELIX RCS is attempting to
establish communication, as this the Unit and AddIn may lose synchronisation.
If online communication cannot be established, check the following
The AddIn device is set to a valid Address, COM Port and Comms Mode in the upper Home tab.
Cabling and power connections are in place.
Network communications are operating correctly (Ethernet setups only) – refer to Section 7.3.4.